In this vignette a PARAFAC model is created for the
Shao2019
data. This is done by first processing the count
data. Subsequently, the appropriate number of components are determined.
Then the PARAFAC model is created and visualized.
The data cube in Shao2019$data contains unprocessed counts. The
function processDataCube()
performs the processing of these
counts with the following steps:
compositions::clr()
function with a pseudo-count of one
(on all features, prior to selection based on sparsity).The outcome of processing is a new version of the dataset called
processedShao
. Please refer to the documentation of
processDataCube()
for more information.
A critical aspect of PARAFAC modelling is to determine the correct
number of components. We have developed the functions
assessModelQuality()
and
assessModelStability()
for this purpose. First, we will
assess the model quality and specify the minimum and maximum number of
components to investigate and the number of randomly initialized models
to try for each number of components.
Note: this vignette reflects a minimum working example for analyzing
this dataset due to computational limitations in automatic vignette
rendering. Hence, we only look at 1-4 components with 5 random
initializations each. These settings are not ideal for real datasets.
Please refer to the documentation of assessModelQuality()
for more information.
# Setup
# For computational purposes we deviate from the default settings
minNumComponents = 1
maxNumComponents = 4
numRepetitions = 5 # number of randomly initialized models
numFolds = 5 # number of jack-knifed models
maxit = 200
ctol= 1e-6 #1e-4 this is a really bad setting but is needed to save computational time
numCores = 1
colourCols = c("Delivery_mode", "phylum", "")
legendTitles = c("Delivery mode", "Phylum", "")
xLabels = c("Subject index", "Feature index", "Time index")
legendColNums = c(3,5,0)
arrangeModes = c(TRUE, TRUE, FALSE)
continuousModes = c(FALSE,FALSE,TRUE)
# Assess the metrics to determine the correct number of components
qualityAssessment = assessModelQuality(processedShao$data, minNumComponents, maxNumComponents, numRepetitions, ctol=ctol, maxit=maxit, numCores=numCores)
The overview plot showcases the number of iterations, the sum-of-squared error, the CORCONDIA and the variance explained for 1-4 components.
The overview plots shows that we can explain 8-10% of the variation in a
three-component model. That is quite low. The CORCONDIA for that number
of components is well above the minimum requirement of 60. However, a
four-component model yields much lower CORCONDIA values.
Next, we investigate the stability of the models when jack-knifing
out samples using assessModelStability()
. This will give us
more information to choose between 3 or 4 components.
stabilityAssessment = assessModelStability(processedShao, minNumComponents=1, maxNumComponents=4, numFolds=numFolds, considerGroups=TRUE,
groupVariable="Delivery_mode", colourCols, legendTitles, xLabels, legendColNums, arrangeModes,
ctol=ctol, maxit=maxit, numCores=numCores)
stabilityAssessment$modelPlots[[1]]
The model is stable for 1-4 components. Hence a three-component is the
appropriate number of components based on the CORCONDIA score.
We have decided that a three-component model is the most appropriate
for the Shao2019
dataset. We can now select one of the
random initializations from the assessNumComponents()
output as our final model. We’re going to select the random
initialisation that corresponded the maximum amount of variation
explained for three components.
numComponents = 3
modelChoice = which(qualityAssessment$metrics$varExp[,numComponents] == max(qualityAssessment$metrics$varExp[,numComponents]))
finalModel = qualityAssessment$models[[numComponents]][[modelChoice]]
Finally, we visualize the model using
plotPARAFACmodel()
.
plotPARAFACmodel(finalModel$Fac, processedShao, 3, colourCols, legendTitles, xLabels, legendColNums, arrangeModes,
continuousModes = c(FALSE,FALSE,TRUE),
overallTitle = "Shao PARAFAC model")
You will observe that the loadings for some modes in some components
are all negative. This is due to sign flipping: two modes having
negative loadings cancel out but describe the same thing as two positive
loadings. The flipLoadings()
function automatically
performs this procedure and also sorts the components by how much
variation they describe.
finalModel = flipLoadings(finalModel, processedShao$data)
plotPARAFACmodel(finalModel$Fac, processedShao, 3, colourCols, legendTitles, xLabels, legendColNums, arrangeModes,
continuousModes = c(FALSE,FALSE,TRUE),
overallTitle = "Shao PARAFAC model")